Home / Technology / RAIN RFID, explained without the jargon

RAIN RFID, explained without the jargon

A tag answers when a reader asks. No line of sight, no one holding a scanner on each item. What changes from one site to another is how well the answer reaches the reader.

Readersends the radio fieldTags answer by reflection

What actually happens in a read

The reader sends a radio signal through an antenna. Tags in range use that energy to wake up and reply with their code. Many tags can answer in the same second, so a full box can be read without opening it. The tags follow the EPC Gen2 standard, and you choose them. Our readers work with the standard ones.

How a reader counts hundreds of tags at once

When many tags answer together, their replies collide. The reader solves this by splitting the tags into time slots, so each one answers on its turn. How many slots it opens depends on how many tags it expects in the field, the population estimate. The reader normally works this estimate out by itself, in real time. In a controlled setup with a known, fixed number of tags, you can set it by hand and read a little faster.

What makes a read better or worse

Reads are a negotiation between several things. Change one and the result changes. When a project reads badly, the cause is almost always on this list.

  • Antenna type and where it points
  • Reader output power, and how much the cable and splitter eat
  • Tag orientation against the antenna's polarization
  • Metal, liquids and people near the tag, which block or detune it
  • The tag model, and whether it was made for that surface
  • Distance between tag and antenna

Materials: what sits between the tag and the reader

The radio wave crosses some materials almost untouched, is absorbed by others and bounces off metal. The material also changes the tag itself: a tag tuned for cardboard can go deaf when it is stuck on a bottle or a steel part. That is why the same reader and antenna can read 100% of one product and struggle with another.

Cardboard, paper, dry wood and plastics

Nearly transparent to the signal. Tags read through them well, even inside closed boxes and stacked totes.

Water, liquids and food

Water absorbs UHF energy. Drinks, fresh meat, fruit and moist products weaken the signal that crosses them, and a tag stuck straight on them loses range. Frozen products absorb much less than fresh ones.

Metal

Metal does not let the signal through: it reflects it. A common tag laid flat on metal stops working, because the metal cancels its antenna. Around a reading zone, metal walls, racks and doors also bounce the signal and can extend reads to places you did not expect.

Glass, ceramics and dense goods

They let the signal pass, but they shift the tag's tuning when the tag is stuck on them. A full pallet of dense goods also hides the tags in the middle from the antenna.

The human body also gets in the way

To a radio wave, a person is mostly water. A body standing between the tag and the antenna absorbs a large part of the signal, and a tag pressed against the skin, in a pocket or on a badge, reads worse than the same tag in free air. In doors, gates and store exits, where people carry the items, this is the main cause of missed reads.

  • Put antennas on both sides of the passage, or overhead, so one of them always sees the tag past the body
  • Count on the worst case: the item hugged against the chest or held on the side away from the antenna
  • For badges and wearables, pick tags made to be worn, with a spacer between the antenna and the body

A tag for each application

There is no universal tag. Every tag is designed for the surface it goes on and the life it will have, and picking the right one solves most of the problems above. Our readers work with any standard EPC Gen2 tag, so you choose the tag by the item, not by the reader.

Labels for each case

Paper or film labels with an inlay inside, printed like a barcode label. There are inlays tuned for cardboard, for garments, for plastic, for glass and for products with liquid. Size and shape also change range and how the tag behaves when it is turned.

On-metal labels and tags

Built with a spacer or a ground layer that turns the metal into part of the antenna instead of a problem. Use them on steel and aluminium parts, tools, gas cylinders, IT equipment and metal racks.

Hard tags

Tags sealed in a rigid housing, such as ABS, polycarbonate or ceramic, screwed, riveted or embedded in the item. They survive impact, washing, heat and outdoor use: returnable pallets and totes, tools, fleet, assets and textile laundry.

Special-purpose tags

Windshield tags for vehicle access, tags for tyres, sewn-in tags for uniforms, tamper-evident tags that break when removed, and tags for high temperature. Each one exists because a common label would fail in that place.

Before you buy tags in volume, test two or three models on your real items, in the position they will really be applied.

Sessions and search modes: who gets read again

Every tag keeps a flag, A or B, for each of four sessions (S0 to S3). When the reader inventories a tag, the flag flips, and the tag goes quiet until the flag returns. How long that takes is the persistence, and it depends on the session. The search mode decides what the reader does with the flag, so it decides how often you see the same tag.

  • Dual target: alternates between A and B tags, so tags keep being read
  • Single target: reads A tags and moves them to B, where they rest until they return to A
  • Single target B to A: the same, with the flags inverted
  • TagFocus (single target with suppression): after being read, tags stay silent while they remain in the field, which cuts repeated reads in dense, static populations

RF mode: speed or sensitivity

The RF mode sets the modulation, the timing and the data rate between reader and tag. Lower data rates give more sensitivity and better resistance to radio interference. Higher data rates read faster, but suffer more from interference. Pick a slower mode for noisy sites with many readers, and a faster one when tags pass quickly.

Near-field or far-field

Near-field antennas read in a tight zone close to the antenna, up to about 1 m on the larger ones. Use them where you must read one item and not its neighbor: a checkout counter, a sorting table. Far-field antennas throw a wider beam over more distance. Use them for doors, aisles and docks.

Think in read zones, not in readers

Start by drawing the space where tags must be read, and the space where they must not. A dock door is a zone. The shelf next to it is not. Then pick antennas whose beam fits the first shape, and set power to stop short of the second. Test with your real items before you install.

What the reader tells you about each read

Besides the tag code (EPC), a read can carry the signal strength (RSSI), the phase, the frequency channel, the antenna that heard the tag and the moment of the read. RSSI helps to compare distances and spot weak reads. Phase is used in movement and location work. The antenna tells you in which zone the tag was. Each reader sends only the fields you switch on.

{"epc":"3035000000000000000121","rssi":-5320,"antenna":1,"timestamp":"1790000000000"}

Test with your real items before you install

Tags behave differently on cardboard, plastic, glass and metal. A bench test with your own items and tags answers most doubts before anyone drills a wall.

  • Place the items as they will really move: in the box, on the pallet, on the shelf
  • Start with the antenna you plan to use and a moderate power, then raise it only if needed
  • Watch the read count and the RSSI while you move the items through the zone
  • Check the neighbors: items that must not be read should stay silent
  • Repeat with the worst case: the fullest pallet, the densest box

Questions we hear

Does RAIN RFID work through boxes?

Yes, through cardboard and plastic. Metal and liquids are the problem. They can block the signal, so test with your own packaging.

Do you sell the tags?

No. Identix makes readers, antennas, modules and portals. They work with standard EPC Gen2 RAIN RFID tags, which you choose for your items.

Why do I read tags I did not want?

The beam or the power is too wide for the space. Use a narrower antenna, lower the power, or move the antenna so it points away from the neighbors.

Why do I keep reading the same tag?

Because the tag keeps answering. The search mode and the session decide how often that happens. A mode with suppression, like TagFocus, makes a tag stay silent after the first read while it is still in the field.

What is the RSSI for?

It shows how strong the tag signal arrived. Use it to compare positions, find weak spots in a zone and tell a close tag from a distant one. It is a relative indicator, not a distance in meters.

Does a person carrying the item hurt the read?

It can. The body absorbs the signal, so a tag hidden behind it or pressed against it reads worse. Antennas on both sides of the passage, or overhead, cover that case.

Can I tag a metal item?

Yes, with an on-metal tag or a hard tag made for metal. A common label stuck flat on metal does not answer.

Need help connecting it?

Talk to an engineer