A transition zone is a door, a store exit, a corridor or a dock: a place items pass through. There you want to read what crosses the line, not what sits beside it, and often to know which way it went. Fan and curtain beams, and the electrical tilt of the 90C4090 and the 85DL4090, are made for that.

Read what passes, not what is nearby

A square 70° x 70° panel lights up a round patch of floor. In a doorway that patch spills into the shelves beside it, and tags parked there get read as if they had passed. A wide-beam antenna squeezes the beam in one plane and keeps it wide in the other. The read zone becomes a strip: wide enough to cover the whole doorway, narrow along the path. Fewer stray reads, and a clearer moment when the item crossed.

shelves inside the storepathdoor70° x 70° panelReaches the shelves: stray readsshelves inside the storepathdoor40° x 90° fanCovers the doorway, spares the shelves

Three antennas, three shapes of beam

All three are panels you can hide in a ceiling, a wall or a portal post. They differ in beam, polarization and size.

65C6095 · curtain beam

60° x 95°, 6.5 dBiC, circular, 900-930 MHz. 245 x 125 x 20 mm and IP65. The beam points straight out from the face, with no tilt. Pick it for narrow passages and portal posts where space is short.

90C4090 · fan beam, circular

40° x 90°, 9 dBiC, one SMA port. The beam leaves the panel tilted 14° at 915 MHz. Circular polarization reads tags in any rotation around the beam, so pick it when items pass in random positions.

85DL4090 · fan beam, dual linear

40° x 90°, 8.5 dBiL, two SMA ports on the same patches: with the long side horizontal, port 1 is vertical and port 2 horizontal. The beam is tilted 15° (port 1) and 14° (port 2) at 915 MHz. Each port reaches farther than a circular antenna in its own polarization, and the reader switches between the two.

Electrical tilt: the beam already leaves at an angle

In the 90C4090 and the 85DL4090 the radiating elements are fed with a growing phase delay from one end of the panel to the other. The beam leans toward one end even with the panel flat on the wall. The tilt happens only in the 40° plane, along the long side. In the 90° plane, across the panel, the beam stays centered.

90° plane: across the panel90°Centered: no tilt40° plane: along the long side≈15°40°off-center screw on the backLeans toward one end
  • 90C4090: 14° at 915 MHz, the middle of its 900-930 MHz band.
  • 85DL4090: 15° on port 1 and 14° on port 2, at 915 MHz.
  • On the back of both, a screw that sits on one end and not on the other marks the end the beam leans to.
  • Mount with the long side horizontal and the beam leans left or right, not down. Mount with the long side vertical and it leans up or down.

Where they fit

Store exit and loss prevention

Antennas in the ceiling or in slim posts at the exit. The narrow plane keeps the clothes rack two meters inside the store out of the zone. The 90C4090 reads hanging garments in any position.

Passage between areas, with direction

Two antennas tilted to opposite sides: one looks at the approach, the other at the way out. If a tag shows up first on A and then on B, it went in. B and then A, it came out.

Docks and wide gates

The 90° plane runs across the opening and covers a wide gate from one point in the ceiling. The 40° plane keeps the trucks and pallets parked beside the gate outside the zone.

Corridors and people passages

Badges, carts and kits that cross a corridor. Antennas on the side walls, beams crossing in an X, read from both sides and see a tag that one body would hide from a single antenna.

GateView OTP: two antennas already aimed

The GateView OTP always comes with two antennas inside: two 90C4090 (circular) or two 85DL4090 (dual linear). They sit 260 mm apart, each on a support tilted 5°, in opposite directions along the long side. The 5° of the support add to the electrical tilt, so each sector points about 20° to one side. Two 40° sectors side by side give the 80° x 90° opening of the portal.

≈20°≈20°40°40°260 mmEach antenna: 5° support + electrical tilt ≈ 20° · two 40° sectors = 80° x 90°Two 90C4090 or two 85DL4090 · section along the long side of the antennas

GateView OTP-7070: one sector straight, one turned 11°

The OTP-7070 uses two 85C7070 antennas, 70° x 70° and circular, with no electrical tilt. They also sit 260 mm apart. One lies flat and points straight at the floor. The other sits on a bend of 11° and points to the outer side. The two 70° x 70° sectors add up to an 80° x 70° opening, wider toward that side, for open areas and gates where the read zone does not need to be narrow.

11°0°260 mmTwo 85C7070, 70° x 70°: one flat, one on an 11° bend · 80° x 70° in total

How big is the zone on the floor

A first estimate, from the angles alone: the edge of each beam where the signal drops by half (-3 dB), drawn down to the height where the tags pass. Real reach also depends on reader power, tag and surroundings, so confirm on site.

Antennas atTags atOne 90C4090 or 85DL4090, flat in the ceilingGateView OTP
2.5 m1.0 m1.2 x 3.0 m2.5 x 3.0 m
3.0 m1.0 m1.6 x 4.0 m3.4 x 4.0 m
3.5 m1.0 m2.0 x 5.0 m4.2 x 5.0 m

Length along the long side of the antennas x width across it. Tilt taken as 15°, GateView OTP sectors at ±20°.

Installation

The step-by-step installation is in the Help Center: how to find the tilt direction on the back of the panel, how to mount the 90C4090 and the 85DL4090 in the ceiling or on side walls, how to install the GateView OTP and OTP-7070, and what to check before you switch on.

Questions we hear

Is the tilt a downtilt?

Only if you mount the panel with its long side vertical. The tilt follows the long side of the panel, so with the long side horizontal the beam leans sideways.

Can I cancel the tilt?

Yes, by tilting the panel the other way with an articulated support. The GateView OTP does the opposite: its supports add 5° to the electrical tilt.

90C4090 or 85DL4090?

Same body and same fan. Pick the 90C4090 when tags pass in any rotation and you want one cable per antenna. Pick the 85DL4090 when you want more reach in each polarization and have two reader ports per antenna.

Need help connecting it?

Talk to an engineer